Pilkington pyrostop 30-20, 18mm
Pilkington · evidence reference CF328 (Warringtonfire Certifire, stated validity to 22 Oct 2029)
Within stated validity to 22 Oct 2029; issuer status still requires checking
This glass can achieve different fire ratings depending on how it is used — internal or external, door or screen, single or double-glazed unit, and the framing system. Each record below must be checked against the current certificate, test regime and complete framing, seals, fixings, installation and exposure. Only explicitly reviewed mappings carry review provenance; other extracted data remains unverified.
Request a quote for this glass
Give us your size and contact details and verified local suppliers will quote — no account needed, just an email to confirm.
Certified options for this glass
Check recorded size bounds and outstanding evidence
A size fit is only one part of qualification. The complete framing, seals, fixings, exposure and current certificate must be checked. No rotation or interpolation between tabulated pairs is assumed.
System verification required
Test regime / source mapping unverified · numeric integrity/insulation minutes do not automatically establish EN 13501 E/EW/EI.
Within stated validity to 22 Oct 2029; issuer status still requires checking
Door
Aluminium
Single
Internal
Size per certificate · 600 × 1800 mm
Confirm the cited system's width, height, area, orientation and any dimension graph; do not assume rotation or interpolation.
- Pyrodur® 30-201 & 30-203 (10 mm thick)
- 45 mm screws, 200 mm centres, fixed at 30o
- System 36/10 glazing channel
- Hardwood beads, 550 kg/m3 min. density, min. 20 mm high by 18.5 mm wide (including 5 mm high by 5 mm wide bolection), square or 15o chamfer
- 2 mm thick Palusol liner
- Nominally 44 mm thick FD30 door leaf
- 38 mm screws, 200 mm centres, fixed at 45o
- Interdens, 10 mm by 2 mm
- Hardwood beads, 640 kg/m3 min. density, min. 24 mm high by 19 mm wide (including 4 mm high by 4 mm wide bolection), square or 15o chamfer
- 12 mm thick hardwood liner
- Fibrefrax tape, 15 mm by 2 mm the proposed dimensions. The specification of the glazing beads and their method of attachment shall also be as tested or CERTIFIRE approved.
Understanding the grades
Integrity for the classified duration. It does not establish radiation control or insulation.
The complete system and classification report determine E performance.
Integrity plus a radiation limit for the classified duration. EW is distinct from E and from EI.
Check radiation performance in the system classification report.
Integrity plus insulation for the classified duration. A BS 476 integrity/insulation pair alone is not an EN 13501 EI classification.
Specify class and minutes from the project fire strategy.
Manufacturer location/exposure terminology, separate from fire-resistance class. Confirm the specific glass, system and installation conditions.
Internal/external suitability cannot be inferred from the letters E, EW or EI.