Skip to main content
← All tools

Glass comparison

Compare two to four supported constructions. Published ratings belong to the stated product and build; planning examples provide construction arithmetic without invented performance.

Choose your builds

3 of 4

Side-by-side

Sourced / derived / unavailable
Selected exact source products or explicitly labelled planning constructions. No structural suitability or ordering approval is implied.
Property6mm clear toughened — planning example6 / 0.76 PVB / 6 — planning examplePilkington Optitherm S3 — 4 / 16Ar / 4
Ordered construction6mm clear toughened6mm clear toughened / 0.76mm PVB (Generic PVB estimate) / 6mm clear toughened4mm clear annealed (Pilkington Optifloat Clear) / 16mm argon cavity (90% fill) / 4mm clear annealed (Pilkington Optitherm S3) (Optitherm S3, face 3)
Nominal total thickness6mm12.76mm24mm including cavities
Estimated mass per m²15.00 kg/m² (glass density estimate)30.84 kg/m² (includes estimated film mass)20.00 kg/m² (glass density estimate)
Glazing Ug (W/m²K)Unavailable for this buildUnavailable for this build1.1 W/m²K
Light transmission (%)Unavailable for this buildUnavailable for this build82%
Solar factor g (0–1)Unavailable for this buildUnavailable for this build0.65
Laboratory Rw (dB)Unavailable for this buildUnavailable for this buildUnavailable for this build
Spectrum adaptation C (dB)Unavailable for this buildUnavailable for this buildUnavailable for this build
Spectrum adaptation Ctr (dB)Unavailable for this buildUnavailable for this buildUnavailable for this build
UV metric (%) — source basis requiredUnavailable for this buildUnavailable for this buildUnavailable for this build
Impact / security classificationNot established by this reference — request evidence for the product and system.Not established by this reference — request evidence for the product and system.Not established by this reference — request evidence for the product and system.
Source and limits

Nominal physical properties only; no tested performance or suitability implied

Sources and scope

Nominal 12.76mm; no structural or acoustic rating

Sources and scope

Historical manufacturer-published exact assembly; vertical, 90% argon, coating face 3. Current supply/DoP to confirm.

Sources and scope

Heat treatment alone does not improve acoustic performance. Low-iron glass reduces iron-related tint; it is not a promise of zero colour. Missing ratings cannot be inferred from another build. Mass excludes cavity gas and uses separately estimated interlayer mass.

Open enquiry draft →
Sources and scope