Solar control glass selector

Compare sourced daylight, solar-gain and glazing-insulation values for supported builds. Choose your priorities and prepare an enquiry without predicting a room's summer temperature.

Your project and priorities

Interactive
Optional performance targets
Examples and guidanceMinimum LT (%)

Leave blank if not specified.

What your choice means

Leave blank if not specified.

Examples and guidanceMaximum g (0–1)

Leave blank if not specified.

What your choice means

Leave blank if not specified.

Examples and guidanceMaximum glazing Ug (W/m²K)

Leave blank if not specified.

What your choice means

Leave blank if not specified.

The shortlist is ordered by your chosen priority. This is a discussion aid; orientation, glazing area, shading, ventilation and building design affect overheating. Source figures describe the stated glazing reference, not your whole window.

5 sourced reference builds match these filters.

Saint-Gobain XTREME 61/29 — 6 / 16Ar / 4

6mm clear annealed (Saint-Gobain COOL-LITE XTREME 61/29 PLANICLEAR) (XTREME 61/29, face 2) / 16mm argon cavity (90% fill) / 4mm clear annealed (Saint-Gobain PLANICLEAR)

LT
61%
g
0.29
Glazing Ug
1 W/m²K

UV: Unavailable for this build. Values from one build cannot be transferred to a different coating, pane thickness, treatment or unit construction.

September 2026 manufacturer DGU reference; vertical glazing-only Ug, not whole-window performance. Confirm current UK product/processing evidence.

Assembly and processing conditions
  • Coating face 2 in an IGU; confirm edge deletion and processing with manufacturer.
  • This selection is the annealed 61/29 reference; the II heat-treatment variant needs its own confirmed specification.
Sources and scope

Saint-Gobain COOL-LITE SKN 165 — 6 / 16 / 4

6mm clear annealed (Saint-Gobain COOL-LITE SKN 165) (COOL-LITE SKN 165, face 2) / 16mm air cavity (100% fill) / 4mm clear annealed (Saint-Gobain PLANICLEAR)

LT
61%
g
0.34
Glazing Ug
Unavailable for this build

UV: Unavailable for this build. Values from one build cannot be transferred to a different coating, pane thickness, treatment or unit construction.

Manufacturer EN410 reference, 6/16/4, face 2. Gas not specified by optical source; air is a planning placeholder. Ug/UV unavailable.

Assembly and processing conditions
  • Must be assembled in an IGU with edge-deleted coating on face 2.
  • SKN 165 II must be tempered; this source selection is annealed SKN 165.
  • An overhead location still requires a project-specific safety/structural specification.
Sources and scope

Pilkington Optitherm S3 — 4 / 16Ar / 4 / 16Ar / 4

4mm clear annealed (Pilkington Optitherm S3) (Optitherm S3, face 2) / 16mm argon cavity (90% fill) / 4mm clear annealed (Pilkington Optifloat Clear) / 16mm argon cavity (90% fill) / 4mm clear annealed (Pilkington Optitherm S3) (Optitherm S3, face 5)

LT
74%
g
0.53
Glazing Ug
0.6 W/m²K

UV: Unavailable for this build. Values from one build cannot be transferred to a different coating, pane thickness, treatment or unit construction.

March 2020 exact vertical triple assembly; 90% argon in both cavities, faces 2 and 5; current DoP to confirm.

Assembly and processing conditions
  • No frame/spacer contribution is included in Ug.
Sources and scope

Pilkington Optitherm S1A — 4 / 16Ar / 4

4mm clear annealed (Pilkington Optifloat Clear) / 16mm argon cavity (90% fill) / 4mm clear annealed (Pilkington Optitherm S1A) (Optitherm S1A, face 3)

LT
76%
g
0.55
Glazing Ug
1 W/m²K

UV: Unavailable for this build. Values from one build cannot be transferred to a different coating, pane thickness, treatment or unit construction.

March 2020 manufacturer assembly; vertical, 90% argon, face 3; current DoP to confirm.

Assembly and processing conditions
  • This is the annealed source assembly; heat treatment needs its own declared product data.
Sources and scope

Pilkington Optitherm S3 — 4 / 16Ar / 4

4mm clear annealed (Pilkington Optifloat Clear) / 16mm argon cavity (90% fill) / 4mm clear annealed (Pilkington Optitherm S3) (Optitherm S3, face 3)

LT
82%
g
0.65
Glazing Ug
1.1 W/m²K

UV: Unavailable for this build. Values from one build cannot be transferred to a different coating, pane thickness, treatment or unit construction.

Historical manufacturer-published exact assembly; vertical, 90% argon, coating face 3. Current supply/DoP to confirm.

Assembly and processing conditions
  • Soft coating remains inside an IGU on face 3 for this reference.
  • Changing treatment, coating, gas/fill or dimensions of layers invalidates this lookup.
Sources and scope

Understanding the trade-offs

LT is visible-light transmission (%); g is solar energy admitted (0–1); glazing Ug is heat transfer through the glazing (W/m²K). Lower g can reduce solar gains, while lower Ug reduces glazing heat loss. Whole-window performance also includes the frame and spacer.

Coating position and heat-treatment requirements are product-specific. The supported assemblies keep their manufacturer-defined coatings and protected surfaces together; changing them needs new data. UV values are shown only when sourced, and UV reduction does not guarantee that furnishings will never fade.

Sources and scope