Skip to main content
Heated sealed glazing

Electrically heated double-glazed units

Sealed glazing with a transparent conductive coating that produces radiant heat when powered. Plan the glass, frame, controls and electrical connection together, then build a specification for your project.

Product guide

Electrically heated double-glazed units

Sealed glazing with a transparent conductive coating that produces radiant heat when powered. Plan the glass, frame, controls and electrical connection together, then build a specification for your project.

A comfortable room beside a clear glazed window in winter.
AI-generated illustration. Appearance varies by specification; this is not an exact product sample.

Electrically heated glass, heated double glazing and radiant heated glazing

Heated glazing incorporates an electrically powered heating function into a specified glass system. The glass, frame, controls, cable route and electrical provision need to be planned together. A photograph cannot establish its rated electrical input or heating output.

Primary room heating and supplementary surface comfort are different briefs. The room's heat loss and available heated glass area need assessment before the system is sized. Request the proposed unit build, rated watts, controls and installation requirements together.

Running costs depend on electrical input, tariff and actual operating hours. Thermostat operation, weather and room use affect energy consumption. An arithmetic cost illustration is not a prediction of energy savings or a substitute for heating design.

Electrically heated double-glazed units for your project

Common enquiry briefs include bi-folding doors, fixed glazed panel, roof infill panel, extension or conservatory. Describe the intended use and the supporting construction so the supplier can assess the complete specification. Different applications can need different glass processing, fixings and installation details.

Glass and heating in one design

The heated coating is part of a sealed glazing system. Frame details, cable routing and controls need to be agreed alongside the panel dimensions.

Match the heating requirement

Primary and supplementary heating are different briefs. The room’s heat loss and available heated area determine what needs to be assessed.

Use the specified electrical input

Ask for rated watts for the actual unit. A running-cost illustration needs that input, your tariff and an operating-time assumption.

What to include in a made-to-measure quote

Compare quotes using the same dimensions, quantities, finish, glass construction and installation scope. If you have a drawing or an existing specification, include its reference and identify which details still need advice.

  • What should the heating do?: A room heat-loss assessment is needed before proposing glass as the primary heat source.
  • Frame and opening arrangement: The glass supply and electrical routing need to suit the actual framing system.
  • Controls and zoning: The supplier must confirm the compatible thermostat, sensors and control equipment.
  • Electrical provision: Record the power-entry position and circuit information in the notes; connections need a qualified electrician.
  • Sealed-unit specification: Include any required depth, glass treatment, cavity and performance targets in the notes.
  • Supply and installation scope: Agree who provides the glazing, compatible controls and electrical work.

Cut-to-size dimensions, edges and fabrication

Measure the finished glass only when the fitting allowances and support details are known. Otherwise identify the opening or existing panel you measured and request a survey. Give each different size its own basket line, with its quantity and drawing reference.

Holes, cut-outs, shaped edges and interfaces with hardware should be settled before manufacture. The finished glass construction and any coatings must suit the intended environment. A screen preview or concept photograph cannot replace a sample, survey or product-specific installation drawing.

Supplier checks before manufacture

  • Confirm the exact unit make-up, frame compatibility, rated electrical input and control system with the supplier.
  • Ask for a room heat-loss assessment if the glass is intended to provide primary heating.
  • Electrical connection and commissioning must follow the chosen system’s instructions and be completed by a qualified installer.

Requesting comparable glass quotes

Save the choices you know and ask for help with the rest. The quote basket records a specification request rather than placing a manufacturing order. A firm quote needs an agreed final build, dimensions, delivery arrangements and any installation or design work.

When comparing proposals, check that glass-only supply and supply with fitting cover the same scope. Ask who provides measurement, drawings, supports, compatible hardware, lifting access and finishing work. Keep the final approved specification with the order.

Sources and further reading

Guided specification · Save multiple sizes · Supplier-confirmed quotes

Your glass, step by step

Build your specification

Choose what you know. Leave the rest for a supplier to advise. Add different sizes as separate basket lines.

No account needed to configure
1. Your project

1What are you making?

2. Glass and performance

2Choose the details

Examples and guidanceHeated glazing, controls and electrical design

A room heat-loss assessment is needed before proposing glass as the primary heat source.

Heated glazing system interfacesHeated panel connected to controls. No internal coating position or electrical connection detail is prescribed.What should the heating do?Illustrative schematic, not to scale or a fabrication / fixing specification.

What your choice means

Heated glazing combines a specified conductive glass surface with electrical connections and controls. The exact coating position, wiring and unit make-up must follow the supplied system rather than a generic pane diagram.

State whether the aim is comfort, condensation control or a designed heating contribution. Ask for rated electrical input, control strategy, frame compatibility and installation requirements; a running-cost example is not a room heat-loss calculation.

Examples you may seeIdentify the power-entry edge and driver or controller position.Have the system supplier and electrical designer confirm the proposed assembly.Available choices: Help me choose; Supplementary room heating; Primary heating — design assessment required; Surface comfort / condensation control.Current choice: Help me choose. This is your request for the supplier to confirm.Electrically heated double-glazed units: original Flow application conceptAI-generated product illustration from Google Flow; not an exact product sample, completed installation or proof of performance.Pilkington: Optitherm low-emissivity glass (opens in a new tab) ↗

A room heat-loss assessment is needed before proposing glass as the primary heat source.

Examples and guidanceHeated glazing, controls and electrical design

The glass supply and electrical routing need to suit the actual framing system.

Heated glazing system interfacesHeated panel connected to controls. No internal coating position or electrical connection detail is prescribed.Frame and opening arrangementIllustrative schematic, not to scale or a fabrication / fixing specification.

What your choice means

Heated glazing combines a specified conductive glass surface with electrical connections and controls. The exact coating position, wiring and unit make-up must follow the supplied system rather than a generic pane diagram.

State whether the aim is comfort, condensation control or a designed heating contribution. Ask for rated electrical input, control strategy, frame compatibility and installation requirements; a running-cost example is not a room heat-loss calculation.

Examples you may seeIdentify the power-entry edge and driver or controller position.Have the system supplier and electrical designer confirm the proposed assembly.Available choices: Help me choose; New aluminium bi-fold system; Existing bi-fold system — compatibility to confirm; Fixed glazing system; Roof glazing system — specialist review.Current choice: Help me choose. This is your request for the supplier to confirm.Electrically heated double-glazed units: original Flow application conceptAI-generated product illustration from Google Flow; not an exact product sample, completed installation or proof of performance.Pilkington: Optitherm low-emissivity glass (opens in a new tab) ↗

The glass supply and electrical routing need to suit the actual framing system.

Examples and guidanceHeated glazing, controls and electrical design

The supplier must confirm the compatible thermostat, sensors and control equipment.

Heated glazing system interfacesHeated panel connected to controls. No internal coating position or electrical connection detail is prescribed.Controls and zoningIllustrative schematic, not to scale or a fabrication / fixing specification.

What your choice means

Heated glazing combines a specified conductive glass surface with electrical connections and controls. The exact coating position, wiring and unit make-up must follow the supplied system rather than a generic pane diagram.

State whether the aim is comfort, condensation control or a designed heating contribution. Ask for rated electrical input, control strategy, frame compatibility and installation requirements; a running-cost example is not a room heat-loss calculation.

Examples you may seeIdentify the power-entry edge and driver or controller position.Have the system supplier and electrical designer confirm the proposed assembly.Available choices: Help me choose; Wall thermostat; Separate room / zone control; Building controls integration — compatibility to confirm.Current choice: Help me choose. This is your request for the supplier to confirm.Electrically heated double-glazed units: original Flow application conceptAI-generated product illustration from Google Flow; not an exact product sample, completed installation or proof of performance.Pilkington: Optitherm low-emissivity glass (opens in a new tab) ↗

The supplier must confirm the compatible thermostat, sensors and control equipment.

Examples and guidanceHeated glazing, controls and electrical design

Record the power-entry position and circuit information in the notes; connections need a qualified electrician.

Heated glazing system interfacesHeated panel connected to controls. No internal coating position or electrical connection detail is prescribed.Electrical provisionIllustrative schematic, not to scale or a fabrication / fixing specification.

What your choice means

Heated glazing combines a specified conductive glass surface with electrical connections and controls. The exact coating position, wiring and unit make-up must follow the supplied system rather than a generic pane diagram.

State whether the aim is comfort, condensation control or a designed heating contribution. Ask for rated electrical input, control strategy, frame compatibility and installation requirements; a running-cost example is not a room heat-loss calculation.

Examples you may seeIdentify the power-entry edge and driver or controller position.Have the system supplier and electrical designer confirm the proposed assembly.Available choices: Help me choose; New electrical provision required; Existing provision — details to follow; Electrical designer / installer appointed.Current choice: Help me choose. This is your request for the supplier to confirm.Electrically heated double-glazed units: original Flow application conceptAI-generated product illustration from Google Flow; not an exact product sample, completed installation or proof of performance.Pilkington: Optitherm low-emissivity glass (opens in a new tab) ↗

Record the power-entry position and circuit information in the notes; connections need a qualified electrician.

Examples and guidanceHeated glazing, controls and electrical design

Include any required depth, glass treatment, cavity and performance targets in the notes.

Heated glazing system interfacesHeated panel connected to controls. No internal coating position or electrical connection detail is prescribed.Sealed-unit specificationIllustrative schematic, not to scale or a fabrication / fixing specification.

What your choice means

Heated glazing combines a specified conductive glass surface with electrical connections and controls. The exact coating position, wiring and unit make-up must follow the supplied system rather than a generic pane diagram.

State whether the aim is comfort, condensation control or a designed heating contribution. Ask for rated electrical input, control strategy, frame compatibility and installation requirements; a running-cost example is not a room heat-loss calculation.

Examples you may seeIdentify the power-entry edge and driver or controller position.Have the system supplier and electrical designer confirm the proposed assembly.Available choices: Help me choose; Supplier to design the complete heated unit; Project specification available; Replacement unit — existing system details available.Current choice: Help me choose. This is your request for the supplier to confirm.Electrically heated double-glazed units: original Flow application conceptAI-generated product illustration from Google Flow; not an exact product sample, completed installation or proof of performance.Pilkington: Optitherm low-emissivity glass (opens in a new tab) ↗

Include any required depth, glass treatment, cavity and performance targets in the notes.

Examples and guidanceItemised scope for this product

Agree who provides the glazing, compatible controls and electrical work.

Numbered specification scheduleA numbered schedule separates panel specification, hardware, delivery, fitting and approvals.Supply and installation scopeIllustrative schematic, not to scale or a fabrication / fixing specification.

What your choice means

Use an itemised quote to separate the product, fabrication, hardware, survey, delivery and installation. Identify work by others and drawing approvals before manufacture.

An optional accessory request does not establish its compatibility with the proposed product. Ask the supplier to confirm the named part, included quantities and any installation requirements.

Examples you may seeSupply only: identify delivery and hardware inclusions.Survey and fitting: identify who confirms final sizes and the supporting construction.Available choices: Help me choose; Glass units only; Glazing and compatible controls; Glazing and installation proposal.Current choice: Help me choose. This is your request for the supplier to confirm.Electrically heated double-glazed units: original Flow application conceptAI-generated product illustration from Google Flow; not an exact product sample, completed installation or proof of performance.Guardian: glass types (opens in a new tab) ↗

Agree who provides the glazing, compatible controls and electrical work.

3. Sizes and fabrication notes

3Size and quantity

Enter finished glass sizes. If you only have opening sizes, ask for a survey or fitting allowance before ordering.

Examples and guidancePanel outline and drawing

Choose the finished outline. A rectangle needs width and height; a circle needs diameter. Bespoke shapes need enough dimensions, radii and datum references to define the outline.

Panel dimension referenceFinished rectangular panel width and height. Opening dimensions are a different reference.ShapeIllustrative schematic, not to scale or a fabrication / fixing specification.

What your choice means

A preview is an illustration; ask the supplier to confirm the manufacturing drawing or template.

Examples you may seeRectangle or square: finished width and height.Circle: diameter, with hole or cut-out positions separately documented.Available choices: Rectangle; Circle; Shaped / drawing to follow.Electrically heated double-glazed units: original Flow application conceptAI-generated product illustration from Google Flow; not an exact product sample, completed installation or proof of performance.Guardian: glass types (opens in a new tab) ↗
Examples and guidanceMeasurement units

1 cm equals 10 mm. Choose the units before entering sizes; keep drawing annotations in the same units.

Panel dimension referenceFinished rectangular panel width and height. Opening dimensions are a different reference.Measurement unitsIllustrative schematic, not to scale or a fabrication / fixing specification.

What your choice means

The form converts entered measurements to the existing millimetre specification fields.

Examples you may see120 cm = 1,200 mm.60 cm = 600 mm.Available choices: Millimetres (mm); Centimetres (cm).Electrically heated double-glazed units: original Flow application conceptAI-generated product illustration from Google Flow; not an exact product sample, completed installation or proof of performance.Guardian: glass types (opens in a new tab) ↗
Examples and guidanceFinished panel dimensions

Record the finished width and height of each distinct panel. For a circle use its diameter; shaped work needs a dimensioned drawing or agreed template.

Panel dimension referenceFinished rectangular panel width and height. Opening dimensions are a different reference.Width ( mm )Illustrative schematic, not to scale or a fabrication / fixing specification.

What your choice means

An opening, frame and finished glass are different references. Request a survey when the finished manufacturing dimensions remain unknown.

Examples you may seeOne size per basket line; quantity records identical pieces.Check units and the dimension reference before confirming manufacture.Electrically heated double-glazed units: original Flow application conceptAI-generated product illustration from Google Flow; not an exact product sample, completed installation or proof of performance.Guardian: glass types (opens in a new tab) ↗
Examples and guidanceFinished panel dimensions

Record the finished width and height of each distinct panel. For a circle use its diameter; shaped work needs a dimensioned drawing or agreed template.

Panel dimension referenceFinished rectangular panel width and height. Opening dimensions are a different reference.Height ( mm )Illustrative schematic, not to scale or a fabrication / fixing specification.

What your choice means

An opening, frame and finished glass are different references. Request a survey when the finished manufacturing dimensions remain unknown.

Examples you may seeOne size per basket line; quantity records identical pieces.Check units and the dimension reference before confirming manufacture.Electrically heated double-glazed units: original Flow application conceptAI-generated product illustration from Google Flow; not an exact product sample, completed installation or proof of performance.Guardian: glass types (opens in a new tab) ↗
Examples and guidanceQuantity of identical pieces

Quantity counts pieces with the same size and specification. Enter different sizes or constructions as separate basket lines so each requirement is retained.

Numbered specification scheduleA numbered schedule separates panel specification, hardware, delivery, fitting and approvals.QuantityIllustrative schematic, not to scale or a fabrication / fixing specification.

What your choice means

Examples you may seeThree identical panels: quantity 3.Two distinct sizes: separate lines.Electrically heated double-glazed units: original Flow application conceptAI-generated product illustration from Google Flow; not an exact product sample, completed installation or proof of performance.Guardian: glass types (opens in a new tab) ↗
Examples and guidanceSealed-unit panes, cavities and edge seal

An insulating glass unit has separate glass panes around one or more sealed cavities. At the perimeter, a spacer maintains separation, with the specified edge-seal system closing the unit. The cavity contains the specified dry air or gas.

Insulating glass unit sectionTwo separate panes around a sealed cavity; a perimeter spacer and edge seal sit between the panes at the bottom edge.Required total unit depth (mm)Illustrative schematic, not to scale or a fabrication / fixing specification.

What your choice means

A double-glazed unit has two panes and one cavity; a triple-glazed unit has three panes and two cavities. Specify pane types and treatments, cavity widths, spacer, gas and seal compatibility separately.

Examples you may seeA 4 / 16 / 4 example totals 24 mm: 4 mm pane, 16 mm cavity, 4 mm pane.A laminated pane within a sealed unit has its own bonded make-up in addition to the unit cavity.Electrically heated double-glazed units: original Flow application conceptAI-generated product illustration from Google Flow; not an exact product sample, completed installation or proof of performance.Guardian: laminated and insulating glass constructions (opens in a new tab) ↗
Optional. Include every pane and cavity; match the frame and glazing beads.
Examples and guidanceDrawing references and unresolved details

Record drawing references, site conditions and requirements not captured in the choices. Identify anything that needs a survey or supplier confirmation before manufacture.

Numbered specification scheduleA numbered schedule separates panel specification, hardware, delivery, fitting and approvals.Project and fabrication notesIllustrative schematic, not to scale or a fabrication / fixing specification.

What your choice means

Examples you may seeNumber drawings and panel positions consistently.State access constraints and the requested work scope.Electrically heated double-glazed units: original Flow application conceptAI-generated product illustration from Google Flow; not an exact product sample, completed installation or proof of performance.Guardian: glass types (opens in a new tab) ↗

0/2000 characters. Share drawings and photos in the job conversation after submitting.

Plan with your own figures

Explore the electricity cost

Use the supplier’s rated electrical input for all the panels you want to run, your electricity tariff and an assumed daily operating time. This illustration uses continuous rated input; thermostat cycling and actual use will change consumption.

Enter all three figures to see an illustration. Ask your supplier for the rated input if it has not yet been specified.

This calculation does not size the heating system or predict savings. For primary heating, use a room heat-loss assessment and the proposed system’s design information.

Before you choose

The decisions that matter

01

Glass and heating in one design

The heated coating is part of a sealed glazing system. Frame details, cable routing and controls need to be agreed alongside the panel dimensions.

02

Match the heating requirement

Primary and supplementary heating are different briefs. The room’s heat loss and available heated area determine what needs to be assessed.

03

Use the specified electrical input

Ask for rated watts for the actual unit. A running-cost illustration needs that input, your tariff and an operating-time assumption.

Ready for a useful supplier quote

  • Confirm the exact unit make-up, frame compatibility, rated electrical input and control system with the supplier.
  • Ask for a room heat-loss assessment if the glass is intended to provide primary heating.
  • Electrical connection and commissioning must follow the chosen system’s instructions and be completed by a qualified installer.

Research behind these choices

Reviewed 23 October 2026. Manufacturer guidance and supplier ordering pages inform these design questions. Agree the final construction and project requirements with your supplier.

Useful questions

Can I get a quote before I know every detail?

Yes. Choose Help me choose where you need advice, or request a site measurement. Suppliers can review the brief; a firm manufacturing price needs an agreed final specification.

Does adding a panel place an order?

No. It saves a specification in your quote basket. Review the basket and provide your delivery details to request supplier quotes. Your configuration does not approve the product for installation.

What should I confirm for heated sealed glazing?

Confirm the exact unit make-up, frame compatibility, rated electrical input and control system with the supplier. Ask for a room heat-loss assessment if the glass is intended to provide primary heating. Electrical connection and commissioning must follow the chosen system’s instructions and be completed by a qualified installer.

Compare related glass